Carrier HVAC Error Code 23: How to Fix It
Medium 30-60 minutes Medium Severity
Verified June 2026
- Error Code
- 23
- Brand
- Carrier
- Product Type
- hvac
- Severity
- Medium
- DIY Difficulty
- Medium
- Estimated Fix Time
- 30-60 minutes
Ad
Tools You'll Need
- Multimeter
- Screwdriver (Phillips/flathead)
- Vacuum cleaner or brush
- Safety gloves and goggles
How to Fix Error Code 23
-
Turn Off Power and Gas
Failure to shut off power and gas can cause electric shock or gas leak. Confirm gas is off. -
Check the Pressure Switch Tubing
-
Inspect and Clean the Vent/Flue
Do not operate the unit with a blocked vent; carbon monoxide can enter your home. -
Test the Pressure Switch with a Multimeter
Use caution when the inducer motor is energized. Do not touch moving parts. -
Check the Inducer Motor Operation
Ensure power is off before touching motor components. -
Verify the Control Board Connections
Only work on the control board with power disconnected to avoid short circuits.
Parts You May Need
Pressure switch
Check Price on Amazon
Inducer motor assembly
Check Price on Amazon
Pressure switch
Check Price on Amazon
Inducer motor assembly
Check Price on Amazon
Pressure switch
Check Price on Amazon
Inducer motor assembly
Check Price on Amazon
Pressure switch
Check Price on Amazon
Inducer motor assembly
Check Price on Amazon
Ad
When to Call a Professional
If you have cleared all blockages, replaced the pressure switch, and the error persists, or if you are uncomfortable working with gas or high voltage, call a licensed HVAC technician. Also if you suspect a heat exchanger crack or gas valve issue.Frequently Asked Questions
What does Carrier error code 23 mean?
It means the pressure switch is not closing, which is required for the furnace to operate safely. Common causes include blocked vent, faulty pressure switch, or failed inducer motor.
Can I bypass the pressure switch to run the furnace?
No, never bypass a pressure switch. It is a safety device that prevents operation if there is a vent blockage or insufficient draft, which could lead to carbon monoxide poisoning.
How do I test a pressure switch with a multimeter?
Disconnect wires and set the multimeter to resistance (ohms). With no air pressure, the switch should be open (infinite resistance). Apply suction with a tube (or run inducer) and the switch should close (near zero ohms).
Where is the pressure switch located on a Carrier HVAC?
It is usually mounted near the inducer motor blower housing, connected by a small rubber tube. On some models, it may be inside the blower compartment.
What tools do I need to fix error 23?
A multimeter to test the switch and inducer motor, a screwdriver to remove panels, and cleaning tools for the vent. You may need replacement parts like a new pressure switch or inducer motor.