Daikin Mini Split Error Code C6: How to Fix It
Medium 30-45 minutes Medium Severity
Verified June 2026
- Error Code
- C6
- Brand
- Daikin
- Product Type
- mini_split
- Severity
- Medium
- DIY Difficulty
- Medium
- Estimated Fix Time
- 30-45 minutes
Ad
Tools You'll Need
- Multimeter
- Screwdriver (Phillips or flathead)
- Needle-nose pliers (optional)
How to Fix Error Code C6
-
Turn Off Power and Access the Indoor Unit
Ensure power is completely disconnected before proceeding to avoid electric shock. -
Locate the Coil Thermistor (R4T)
-
Disconnect and Test the Thermistor
Handle the multimeter leads carefully to avoid shorting the pins. -
Check Wiring and Connectors
-
Replace the Faulty Thermistor
Ensure the replacement thermistor matches the original resistance curve (typically 10kΩ at 25°C). -
Reassemble and Test
Parts You May Need
Daikin coil thermistor (R4T replacement)
Check Price on Amazon
Wire connectors or crimp terminals
Check Price on Amazon
Daikin coil thermistor (R4T replacement)
Check Price on Amazon
Wire connectors or crimp terminals
Check Price on Amazon
Daikin coil thermistor (R4T replacement)
Check Price on Amazon
Wire connectors or crimp terminals
Check Price on Amazon
Daikin coil thermistor (R4T replacement)
Check Price on Amazon
Wire connectors or crimp terminals
Check Price on Amazon
Ad
When to Call a Professional
If the thermistor tests fine (correct resistance) and wiring is good, the control board might be faulty. Replacing the board requires advanced electrical knowledge and should be done by a certified HVAC technician. Also, if you're uncomfortable working with electronics or exposing coil tubing, call a professional.Frequently Asked Questions
Can I bypass the coil thermistor temporarily?
No, bypassing the thermistor can cause the system to run dangerously or not operate at all. It must be replaced with a correct thermistor.
What causes the coil thermistor to short?
Moisture, corrosion, physical damage, or age-related wear can cause a short circuit in the thermistor.
How much does a replacement coil thermistor cost?
A generic Daikin coil thermistor costs between $10 and $30. Always verify compatibility with your unit model.
Can I clean the thermistor instead of replacing it?
Cleaning won't fix a short circuit. If it's shorted, replacement is necessary. You can gently clean the exterior with a dry cloth, but internal damage requires replacement.
Will error code C6 clear automatically after fixing?
Yes, once the short is resolved and power is cycled, the error code should clear. If it doesn't, there may be another issue.