Generac Generator Error Code 1518: How to Fix It
Medium 1-2 hours Medium Severity
Verified June 2026
- Error Code
- 1518
- Brand
- Generac
- Product Type
- generator
- Severity
- Medium
- DIY Difficulty
- Medium
- Estimated Fix Time
- 1-2 hours
Ad
Tools You'll Need
- Multimeter with diode test and ohms function
- Screwdrivers (Phillips and flathead)
- Wrench set (for battery terminals)
- Safety gloves and glasses
How to Fix Error Code 1518
-
Safety First: Disconnect Power
Generator capacitors can hold a lethal charge. Wait 10 minutes after shutdown before touching any components. -
Inspect Wiring and Connections
-
Test the Rotor (Field) Winding
-
Test the Diodes in the Rotor
-
Test the Voltage Regulator
Do not run the generator with the rotor disconnected, as it may damage the regulator. -
Check for Overload or Ground Fault
Parts You May Need
Rotor (field winding) assembly
Check Price on Amazon
Voltage regulator
Check Price on Amazon
Rotor (field winding) assembly
Check Price on Amazon
Voltage regulator
Check Price on Amazon
Rotor (field winding) assembly
Check Price on Amazon
Voltage regulator
Check Price on Amazon
Rotor (field winding) assembly
Check Price on Amazon
Voltage regulator
Check Price on Amazon
Ad
When to Call a Professional
If you are not comfortable with electrical diagnostics or the rotor/voltage regulator tests indicate a faulty component that requires disassembly of the generator end, call a certified Generac technician. Also, if the error persists after replacing parts, professional diagnosis is recommended.Frequently Asked Questions
Can I reset error code 1518 on my Generac generator?
Yes, after fixing the underlying issue, you can usually clear the error by cycling the generator's breaker or disconnecting the battery for a few minutes. However, if the problem is not resolved, the code will return.
What causes field current overload in a generator?
Common causes include a shorted diode in the rotor, a faulty voltage regulator, damaged wiring, or an overload condition. The field current can spike if the regulator tries to compensate for a weak output.
How much does it cost to fix error 1518?
If you DIY and replace the rotor or voltage regulator, parts cost between $50 and $200. Professional repair including labor may range from $300 to $600.
Can I still run my generator with error 1518?
No. Running the generator with a field current overload can damage the alternator and cause further electrical issues. Stop using the generator immediately and troubleshoot.
What is the difference between field current and output voltage?
Field current is the current flowing through the rotor to create a magnetic field. Output voltage is the AC voltage generated in the stator. A high field current often indicates a problem with the magnetic circuit or regulator.