Goodman HVAC Error Code 11: How to Fix It

Medium 30-60 minutes Medium Severity Verified June 2026
Error Code
11
Brand
Goodman
Product Type
hvac
Severity
Medium
DIY Difficulty
Medium
Estimated Fix Time
30-60 minutes
Error code 11 on a Goodman HVAC system indicates that the compressor is not running. This can be caused by a faulty capacitor, a bad contactor, loose wiring, or a failed compressor. Follow these steps to diagnose and fix the issue safely.
Ad

Tools You'll Need

How to Fix Error Code 11

  1. Power Off and Safety Check

    Always disconnect power before servicing HVAC equipment to avoid electrical shock.
  2. Inspect the Contactor

    Be careful not to touch live wires.
  3. Test the Start/Run Capacitor

    Capacitors can hold a dangerous charge even when power is off. Discharge them properly before testing.
  4. Check Wiring Connections

  5. Test Compressor Windings

    Only perform this test if comfortable with electrical diagnostics. If unsure, call a technician.

Parts You May Need

Run capacitor (dual run 35/5 µF or as specified)
Check Price on Amazon
Contactor (24V coil, 30A or 40A rated)
Check Price on Amazon
Run capacitor (dual run 35/5 µF or as specified)
Check Price on Amazon
Contactor (24V coil, 30A or 40A rated)
Check Price on Amazon
Run capacitor (dual run 35/5 µF or as specified)
Check Price on Amazon
Contactor (24V coil, 30A or 40A rated)
Check Price on Amazon
Run capacitor (dual run 35/5 µF or as specified)
Check Price on Amazon
Contactor (24V coil, 30A or 40A rated)
Check Price on Amazon
Ad

When to Call a Professional

If the compressor is burned out (open windings) or if you are not comfortable working with high voltage, call a licensed HVAC technician. Also call if the compressor is shorted to ground (low resistance to ground) or if the system has refrigerant issues.

Frequently Asked Questions

Can I reset Goodman error code 11 myself?
Yes, but only after fixing the underlying issue. Turn off power to the unit for 5 minutes, then restore power. If the problem persists, the error will reappear.
What does error code 11 mean on Goodman AC?
It means the compressor is not running, often due to a faulty capacitor, contactor, or wiring issue.
How do I test a Goodman AC capacitor?
Use a multimeter set to capacitance (µF). Discharge the capacitor, then touch the probes to the terminals. Compare the reading to the rated value; replace if it's more than 10% off.
Is it safe to replace a contactor myself?
Yes, if you have basic electrical knowledge and the power is off. Match the amp and voltage ratings exactly. Otherwise, hire a professional.
How much does it cost to fix Goodman error code 11?
If you DIY, a capacitor costs $10-$30, a contactor $20-$50. Professional service including diagnosis and repair typically ranges from $150-$400.