Goodman HVAC Error Code 27: How to Fix It
Medium 30-60 minutes Medium Severity
Verified June 2026
- Error Code
- 27
- Brand
- Goodman
- Product Type
- hvac
- Severity
- Medium
- DIY Difficulty
- Medium
- Estimated Fix Time
- 30-60 minutes
Ad
Tools You'll Need
- Multimeter with ohms and AC voltage functions
- Non-contact voltage tester
- Screwdriver set
- Wire strippers/cutters (optional)
How to Fix Error Code 27
-
Turn Off Power to the Unit
Hazardous voltage inside the unit. Always disconnect power before servicing. -
Locate the Reversing Valve and Solenoid
-
Check Solenoid Wiring and Connections
-
Test the Solenoid Coil Resistance
Use a multimeter with appropriate safety rating for HVAC equipment. -
Check Control Voltage
Live voltage present. Be careful not to short terminals. -
Replace the Solenoid Coil (if needed)
Use a coil that matches your unit's specifications. -
Test Operation
Parts You May Need
Reversing valve solenoid coil
Check Price on Amazon
Reversing valve solenoid coil
Check Price on Amazon
Reversing valve solenoid coil
Check Price on Amazon
Reversing valve solenoid coil
Check Price on Amazon
Ad
When to Call a Professional
If you've replaced the solenoid coil and the error persists, or if the reversing valve is physically stuck, call a licensed HVAC technician. Diagnosing refrigerant-related issues requires specialized training and equipment.Frequently Asked Questions
What does error code 27 mean on a Goodman heat pump?
Error code 27 indicates an open circuit in the reversing valve solenoid coil, which prevents the heat pump from switching between heating and cooling modes.
Can I drive my Goodman heat pump with error code 27?
Yes, but it will be stuck in one mode (heating or cooling). For example, in winter it may only cool, which could damage the system. Should be repaired promptly.
How do I test the reversing valve solenoid on a Goodman unit?
Use a multimeter to check resistance across the solenoid terminals (should be 20-200 ohms) and check for 24VAC at the solenoid when the system calls for a mode change.
How much does it cost to fix error code 27 on a Goodman system?
DIY solenoid coil replacement costs $20-$50. If a technician replaces the entire reversing valve, costs range from $400-$800.
Can a thermostat cause error code 27?
Yes, a faulty thermostat or wiring can fail to send 24VAC to the solenoid, resulting in the error. Check thermostat signals before replacing the solenoid.