Trane HVAC Error Code 22: How to Fix Inverter Board Over Temperature

Hard 1-2 hours Medium Severity Verified June 2026
Error Code
22
Brand
Trane
Product Type
hvac
Severity
Medium
DIY Difficulty
Hard
Estimated Fix Time
1-2 hours
Error code 22 on a Trane HVAC system means the inverter board has detected an over-temperature condition. This usually happens when the inverter board gets too hot due to poor airflow, a faulty fan, or a malfunctioning board. Fixing it promptly can prevent further damage to the system.
Ad

Tools You'll Need

How to Fix Error Code 22

  1. Power Down the System

    Always turn off power before working on HVAC equipment to avoid electric shock.
  2. Locate the Inverter Board and Fan

  3. Check for Airflow Obstructions

    Do not use water or liquid cleaners near electrical components.
  4. Test the Cooling Fan

    Use caution with live voltage testing. If unsure, call a professional.
  5. Check Inverter Board Temperature Sensor

    Disconnect power before handling the inverter board.
  6. Replace Inverter Board if Needed

    Only attempt board replacement if you have experience with HVAC electronics. Incorrect installation can cause further damage.
  7. Restore Power and Test

Parts You May Need

Inverter board cooling fan
Check Price on Amazon
Inverter board temperature sensor
Check Price on Amazon
Inverter board cooling fan
Check Price on Amazon
Inverter board temperature sensor
Check Price on Amazon
Inverter board cooling fan
Check Price on Amazon
Inverter board temperature sensor
Check Price on Amazon
Inverter board cooling fan
Check Price on Amazon
Inverter board temperature sensor
Check Price on Amazon
Ad

When to Call a Professional

If you are not comfortable working with high-voltage electronics, or if replacing the inverter board does not resolve the error, call a licensed HVAC technician. Also, if the error occurs frequently, a professional diagnosis is recommended.

Frequently Asked Questions

Can I run my Trane HVAC with error code 22?
It is not recommended. Running the system with an over-temperature inverter board can cause permanent damage to the board or other components. Turn off the system and troubleshoot.
How much does it cost to fix Trane error code 22?
DIY repair costs may include a replacement inverter board ($200-$500) or fan ($20-$50). Professional service can range from $150-$400 for labor plus parts.
What causes the inverter board to overheat?
Common causes include a failed cooling fan, blocked airflow (dirt/debris), a faulty temperature sensor, or a failing inverter board that runs hot.